NeoPaint

NeoPaint

NeoPaint is a raster graphics editor for Windows and MS-DOS. It supports several file formats including JPEG, GIF, BMP, PNG, and TIFF. The developer, NeoSoft, advertises NeoPaint as "being simple enough for use by children while remaining powerful enough for the purposes of advanced image editing". The first version, NeoPaint 1.0, was released in 1992 on floppy disks. It supported video modes ranging from 640x350 to 1024x768 and multiple fonts. NeoPaint 2.2 came out for MS-DOS 3.1 in 1993, with support of for 2, 16, or 256 color images in Hercules, EGA, VGA, and Super VGA modes. NeoPaint 3.1 was released in 1995 supporting 24-bit images and formats like PCX, TIFF and BMP. NeoPaint 3.2 was released in 1996. An updated version, NeoPaint 3.2a, supported the GIF file format. NeoPaint 3.2d was released in 1998. A Windows 95 version named NeoPaint for Windows v4.0 was released in 1999 supporting the PNG file format. On September 1, 2018 the program was rebranded as PixelNEO, becoming one of the VisualNEO software products. Formats such as JPEG 2000, ICO, CUR, PSD and RAW are supported.

List of Ruby software and tools

This is a list of software and programming tools for the Ruby programming language, which includes libraries, web frameworks, implementations, tools, and related projects. == Web tools == Capistrano (software) – remote server automation tool Mongrel – Ruby web server Rack – interface between web servers and web applications Ruby on Rails – full-stack web application framework Sinatra – lightweight Ruby web application framework Spree Commerce – e-commerce platform WEBrick – Ruby HTTP server toolkit == Libraries == BioRuby – bioinformatics and computational biology library for Ruby Bogus – Ruby library for creating reliable test doubles with contract verification ERuby – embedded Ruby templating EventMachine – event-driven I/O library Factory Bot – test fixtures library Fat comma – Ruby library for JSON-like hash syntax Geocoder – Ruby library for geocoding and reverse geocoding addresses Haml – HTML templating engine Markaby – HTML generation via Ruby Nokogiri – XML/HTML parsing library RSpec – behavior-driven testing framework for Ruby RubyGems – package manager for Ruby libraries and applications Sass – CSS preprocessor Sidekiq – background job framework for Ruby, used to handle asynchronous tasks. Uconv – Unicode text conversion library Watir – web application testing framework == Ruby implementations == HotRuby – Ruby interpreter implemented in JavaScript, enabling Ruby code to run in web browsers. IronRuby – Ruby for .NET platform JRuby – Ruby on the Java Virtual Machine MacRuby – Ruby implementation for macOS Mod ruby – Apache module that embeds the Ruby interpreter to improve performance of Ruby web applications Mruby – lightweight Ruby interpreter Rubinius – alternative Ruby implementation, based loosely on the Smalltalk-80 Blue Book design. Ruby MRI – the standard Ruby interpreter YARV – "Yet Another Ruby VM," the bytecode interpreter used in modern Ruby implementations == Tools == Homebrew – package manager for macOS and Linux written in Ruby Pry – interactive Ruby shell Rake – build and task management Ruby Version Manager – environment manager RubyCocoa – bridge between Ruby and Cocoa RubyForge – project hosting site RubyMotion – for iOS/macOS development RubySpec – language specification tests == Integrated Development Environments == Aptana Studio — integrated RadRails plugin for Ruby on Rails development Eclipse DLTK Ruby Plugin — Ruby development plugin for Eclipse Eric — open-source Python-based IDE with Ruby support Komodo IDE — commercial cross-platform IDE with Ruby support RubyMine — commercial IDE for Ruby and Rails by JetBrains SlickEdit — commercial cross-platform IDE with Ruby support == List of websites using Ruby on Rails == Airbnb Basecamp Diaspora – decentralized social network application built with Ruby on Rails Discourse – open-source discussion platform built with Ruby on Rails Fiverr GitHub Hulu Shopify SoundCloud Twitch Zendesk

Teleradiology

Teleradiology is the transmission of radiological patient images from procedures such as x-rays, Computed tomography (CT), and MRI imaging, from one location to another for the purposes of sharing studies with other radiologists and physicians. Teleradiology allows radiologists to provide services without actually having to be at the location of the patient. This is particularly important when a sub-specialist such as an MRI radiologist, neuroradiologist, pediatric radiologist, or musculoskeletal radiologist is needed, since these professionals are generally only located in large metropolitan areas working during daytime hours. Teleradiology allows for specialists to be available at all times. Teleradiology utilizes standard network technologies such as the Internet, telephone lines, wide area networks, local area networks (LAN) and the latest advanced technologies such as medical cloud computing. Specialized software is used to transmit the images and enable the radiologist to effectively analyze potentially hundreds of images of a given study. Technologies such as advanced graphics processing, voice recognition, artificial intelligence, and image compression are often used in teleradiology. Through teleradiology and mobile DICOM viewers, images can be sent to another part of the hospital or to other locations around the world with equal effort. Teleradiology is a growth technology given that imaging procedures are growing approximately 15% annually against an increase of only 2% in the radiologist population. == Reports == Teleradiology services commonly provide either preliminary or final interpretations of medical imaging studies. Preliminary reads are frequently used in emergency settings to support immediate clinical decisions and may include direct communication of critical findings to the referring physician. Some providers report turnaround times of approximately 30 minutes for emergency cases, with faster processing for time-sensitive conditions such as stroke. Final reads are definitive and used in official patient records and billing. These reports typically include all relevant findings and may require access to prior imaging and clinical data. Teleradiology is also employed to provide off-hour or overflow coverage for healthcare institutions lacking continuous on-site radiology staffing. == Subspecialties == Some teleradiologists are fellowship trained and have a wide variety of subspecialty expertise including such difficult-to-find areas as neuroradiology, pediatric neuroradiology, thoracic imaging, musculoskeletal radiology, mammography, and nuclear cardiology. There are also various medical practitioners who are not radiologists that take on studies in radiology to become sub specialists in their respected fields, an example of this is dentistry where oral and maxillofacial radiology allows those in dentistry to specialize in the acquisition and interpretation of radiographic imaging studies performed for diagnosis of treatment guidance for conditions affecting the maxillofacial region. == Teleultrasound == Teleradiology infrastructure has also been adapted to support point-of-care ultrasound (POCUS) in remote and austere environments. In teleultrasound—also known as telementored ultrasound—a remote expert guides a non-specialist in real time during image acquisition. This technique has been successfully demonstrated in extreme settings, including aboard the International Space Station, on Mount Everest, and during helicopter flight. == Regulations == In the United States, Medicare and Medicaid laws require the teleradiologist to be on U.S. soil in order to qualify for reimbursement of the Final Read. In addition, advanced teleradiology systems must also be HIPAA compliant, which helps to ensure patients' privacy. HIPAA (Health Insurance Portability and Accountability Act of 1996) is a uniform, federal floor of privacy protections for consumers. It limits the ways that entities can use patients' personal information and protects the privacy of all medical information no matter what form it is in. Quality teleradiology must abide by important HIPAA rules to ensure patients' privacy is protected. Also State laws governing the licensing requirements and medical malpractice insurance coverage required for physicians vary from state to state. Ensuring compliance with these laws is a significant overhead expense for larger multi-state teleradiology groups. Medicare (Australia) has identical requirements to that of the United States, where the guidelines are provided by the Department of Health and Ageing, and government based payments fall under the Health Insurance Act. The regulations in Australia are also conducted at both federal and state levels, ensuring that strict guidelines are adhered to at all times, with regular yearly updates and amendments are introduced (usually around March and November of every year), ensuring that the legislation is kept up to date with changes in the industry. One of the most recent changes to Medicare and radiology / teleradiology in Australia was the introduction of the Diagnostic Imaging Accreditation Scheme (DIAS) on 1 July 2008. DIAS was introduced to further improve the quality of Diagnostic Imaging and to amend the Health Insurance Act. == Industry growth == Until the late 1990s teleradiology was primarily used by individual radiologists to interpret occasional emergency studies from offsite locations, often in the radiologists home. The connections were made through standard analog phone lines. Teleradiology expanded rapidly as the growth of the internet and broad band combined with new CT scanner technology to become an essential tool in trauma cases in emergency rooms throughout the country. The occasional 2–3 x-ray studies a week soon became 3–10 CT scans, or more, a night. Because ER physicians are not trained to read CT scans or MRIs, radiologists went from working 8–10 hours a day, five and half days a week to a schedule of 24 hours a day, 7 days a week coverage. This became a particularly acute challenge in smaller rural facilities that only had one solo radiologist with no other to share call. These circumstances spawned a post-dot.com boom of firms and groups that provided medical outsourcing, off-site teleradiology on-call services to hospitals and Radiology Groups around the country. As an example, a teleradiology firm might cover trauma at a hospital in Indiana with doctors based in Texas. Some firms even used overseas doctors in locations like Australia and India. Nighthawk, founded by Paul Berger, was the first to station U.S. licensed radiologists overseas (initially Australia and later Switzerland) to maximize the time zone difference to provide nightcall in U.S. hospitals. Currently, teleradiology firms are facing pricing pressures. Industry consolidation is likely as there are more than 500 of these firms, large and small, throughout the United States.

Customer support

Customer support is a range of services to assist customers in making cost effective and correct use of a product. It includes assistance in planning, installation, training, troubleshooting, maintenance, upgrading, and disposal of a product. Regarding technology products such as mobile phones, televisions, computers, software products or other electronic or mechanical goods, it is termed technical support. It aims to ensure users can effectively operate the product and resolve any issues that may arise throughout its lifecycle. Support is delivered through various channels, including telephone, email, live chat, self-service knowledge bases, and social media. Research indicates that most customers attempt to resolve issues through self-service before contacting a representative. For products sold across multiple regions, support may be provided in several languages, as consumers tend to prefer assistance in their native language. Requirements for customer contact centres are defined in international standards such as ISO 18295.

Single particle analysis

Single particle analysis is a group of related computerized image processing techniques used to analyze images from transmission electron microscopy (TEM). These methods were developed to improve and extend the information obtainable from TEM images of particulate samples, typically proteins or other large biological entities such as viruses. Individual images of stained or unstained particles are very noisy, making interpretation difficult. Combining several digitized images of similar particles together gives an image with stronger and more easily interpretable features. An extension of this technique uses single particle methods to build up a three-dimensional reconstruction of the particle. Using cryo-electron microscopy it has become possible to generate reconstructions with sub-nanometer, near-atomic resolution resolution first in the case of highly symmetric viruses, and now in smaller, asymmetric proteins as well. == Techniques == Single particle analysis can be done on both negatively stained and vitreous ice-embedded transmission electron cryomicroscopy (CryoTEM) samples. Single particle analysis methods are, in general, reliant on the sample being homogeneous, although techniques for dealing with conformational heterogeneity are being developed. Images (micrographs) are taken with an electron microscope using charged-coupled device (CCD) detectors coupled to a phosphorescent layer (in the past, they were instead collected on film and digitized using high-quality scanners). The image processing is carried out using specialized software programs, often run on multi-processor computer clusters. Depending on the sample or the desired results, various steps of two- or three-dimensional processing can be done. === Alignment and classification === Biological samples, and especially samples embedded in thin vitreous ice, are highly radiation sensitive, thus only low electron doses can be used to image the sample. This low dose, as well as variations in the metal stain used (if used) means images have high noise relative to the signal given by the particle being observed. By aligning several similar images to each other so they are in register and then averaging them, an image with higher signal-to-noise ratio can be obtained. As the noise is mostly randomly distributed and the underlying image features constant, by averaging the intensity of each pixel over several images only the constant features are reinforced. Typically, the optimal alignment (a translation and an in-plane rotation) to map one image onto another is calculated by cross-correlation. However, a micrograph often contains particles in multiple different orientations and/or conformations, and so to get more representative image averages, a method is required to group similar particle images together into multiple sets. This is normally carried out using one of several data analysis and image classification algorithms, such as multi-variate statistical analysis and hierarchical ascendant classification, or k-means clustering. Often data sets of tens of thousands of particle images are used, and to reach an optimal solution an iterative procedure of alignment and classification is used, whereby strong image averages produced by classification are used as reference images for a subsequent alignment of the whole data set. === Image filtering === Image filtering (band-pass filtering) is often used to reduce the influence of high and/or low spatial frequency information in the images, which can affect the results of the alignment and classification procedures. This is particularly useful in negative stain images. The algorithms make use of fast Fourier transforms (FFT), often employing Gaussian shaped soft-edged masks in reciprocal space to suppress certain frequency ranges. High-pass filters remove low spatial frequencies (such as ramp or gradient effects), leaving the higher frequencies intact. Low-pass filters remove high spatial frequency features and have a blurring effect on fine details. === Contrast transfer function === Due to the nature of image formation in the electron microscope, bright-field TEM images are obtained using significant underfocus. This, along with features inherent in the microscope's lens system, creates blurring of the collected images visible as a point spread function. The combined effects of the imaging conditions are known as the contrast transfer function (CTF), and can be approximated mathematically as a function in reciprocal space. Specialized image processing techniques such as phase flipping and amplitude correction / Wiener filtering can (at least partially) correct for the CTF, and allow high resolution reconstructions. === Three-dimensional reconstruction === Transmission electron microscopy images are projections of the object showing the distribution of density through the object, similar to medical X-rays. By making use of the projection-slice theorem a three-dimensional reconstruction of the object can be generated by combining many images (2D projections) of the object taken from a range of viewing angles. Proteins in vitreous ice ideally adopt a random distribution of orientations (or viewing angles), allowing a fairly isotropic reconstruction if a large number of particle images are used. This contrasts with electron tomography, where the viewing angles are limited due to the geometry of the sample/imaging set up, giving an anisotropic reconstruction. Filtered back projection is a commonly used method of generating 3D reconstructions in single particle analysis, although many alternative algorithms exist. Before a reconstruction can be made, the orientation of the object in each image needs to be estimated. Several methods have been developed to work out the relative Euler angles of each image. Some are based on common lines (common 1D projections and sinograms), others use iterative projection matching algorithms. The latter works by beginning with a simple, low resolution 3D starting model and compares the experimental images to projections of the model and creates a new 3D to bootstrap towards a solution. Methods are also available for making 3D reconstructions of helical samples (such as tobacco mosaic virus), taking advantage of the inherent helical symmetry. Both real space methods (treating sections of the helix as single particles) and reciprocal space methods (using diffraction patterns) can be used for these samples. === Tilt methods === The specimen stage of the microscope can be tilted (typically along a single axis), allowing the single particle technique known as random conical tilt. An area of the specimen is imaged at both zero and at high angle (~60-70 degrees) tilts, or in the case of the related method of orthogonal tilt reconstruction, +45 and −45 degrees. Pairs of particles corresponding to the same object at two different tilts (tilt pairs) are selected, and by following the parameters used in subsequent alignment and classification steps a three-dimensional reconstruction can be generated relatively easily. This is because the viewing angle (defined as three Euler angles) of each particle is known from the tilt geometry. 3D reconstructions from random conical tilt suffer from missing information resulting from a restricted range of orientations. Known as the missing cone (due to the shape in reciprocal space), this causes distortions in the 3D maps. However, the missing cone problem can often be overcome by combining several tilt reconstructions. Tilt methods are best suited to negatively stained samples, and can be used for particles that adsorb to the carbon support film in preferred orientations. The phenomenon known as charging or beam-induced movement makes collecting high-tilt images of samples in vitreous ice challenging. === Map visualization and fitting === Various software programs are available that allow viewing the 3D maps. These often enable the user to manually dock in protein coordinates (structures from X-ray crystallography, NMR, or a computational model such as one found in the AlphaFold Protein Structure Database) of subunits into the electron density. Several programs can also fit subunits computationally; as of the 2020s using these programs tend to produce better accuracy than manual docking because they can perform labor-intensive tasks such as: The scale of SPA-derived maps depends on knowing the pixel size (angstorms per pixel), which is not always accurate. Programs can automatically correct for this difference by using coordinate data or by using knowledge of chemical bonds. Many proteins are made up of several roughly rigid protein domains linked by flexible parts. Pre-existing coordinate data, whether experimental or computational, may not exactly match the inter-domain positioning of the cyro-EM map. Modern programs can automatically "chop" pre-existing coordinate data into individual domains and fit them in individually. For higher-resolution structures, it is pos

Joox

Joox (stylised in all caps) is a music streaming service owned by Tencent, launched in January 2015. Joox is the biggest music streaming app in Asian markets such as Hong Kong, Macau, Indonesia, Malaysia, Myanmar, Thailand and also in South Africa before it was shut down in early 2022. Joox is a freemium service, providing most of its songs free, while some songs are only available for premium users, offered via paid subscriptions or by doing different tasks offered. In 2017, Joox launched their service in their first non-Asian market, South Africa, which for an unknown reason shut down five years later. The service now accounts for more than 50% of all music streaming app downloads in their Asian markets. The number of music-streaming users in Hong Kong, Macau, Malaysia, Thailand, Myanmar and Indonesia was expected to reach 87 million by 2020. == Background == Before the emergence of Joox, Tencent owned QQ Music, one of the largest music streaming and download service in China. In 2015, they introduced Joox as their expansion of music services to overseas market instead of mainland China, starting first in Hong Kong. Instead of providing free services by playing audio ads to users like Spotify, another major music service, Joox focused on banner ads, splash ads and other advertising methods such as category playlists and in-app skins. They claimed it as a success. Joox offered their premium VIP access to DStv subscribers free of charge. DStv is the sister company to Tencent and is the primary pay-TV provider in South Africa. In November 2021, it was announced that Joox will stop streaming in South Africa in March 2022.

Cinema 4D

Cinema 4D is a 3D software suite developed by the German company Maxon. == Overview == As of R21, only a single version of Cinema 4D is available. It replaces all previous variants, including BodyPaint 3D, and includes all features of the past 'Studio' variant. With R21, all binaries were unified. There is no technical difference between commercial, educational, or demo versions. The difference is now only in licensing. 2014 saw the release of Cinema 4D Lite, which came packaged with Adobe After Effects Creative Cloud 2014. "Lite" acts as an introductory version, with many features withheld. This is part of a partnership between the two companies, where a Maxon-produced plug-in, called Cineware, allows any variant to create a seamless workflow with After Effects. The "Lite" variant is dependent on After Effects CC, needing the latter application running to launch, and is only sold as a package component included with After Effects CC through Adobe. Initially, Cinema 4D was developed for Amiga computers in the early 1990s, and the first three versions of the program were available exclusively for that platform. With v4, however, Maxon began to develop the application for Windows and Macintosh computers as well, citing the wish to reach a wider audience and the growing instability of the Amiga market following Commodore's bankruptcy. It was also released for BeOS. On Linux, Cinema 4D is available as a commandline rendering version. == Modules and older variants == From R12 to R20, Cinema 4D was available in four variants. A core Cinema 4D 'Prime' application, a 'Broadcast' version with additional motion-graphics features, 'Visualize,' which adds functions for architectural design and 'Studio,' which includes all modules. From Release 8 until Release 11.5, Cinema 4D had a modular approach to the application, with the ability to expand upon the core application with various modules. This ended with Release 12, though the functionality of these modules remains in the different flavors of Cinema 4D (Prime, Broadcast, Visualize, Studio) The old modules were: Advanced Render (global illumination/HDRI, caustics, ambient occlusion and sky simulation) BodyPaint 3D (direct painting on UVW meshes; now included in the core. In essence Cinema 4D Core/Prime and the BodyPaint 3D products are identical. The only difference between the two is the splash screen that is shown at startup and the default user interface.) Dynamics (for simulating soft body and rigid body dynamics) Hair (simulates hair, fur, grass, etc.) MOCCA (character animation and cloth simulation) MoGraph (Motion Graphics procedural modelling and animation toolset) NET Render (to render animations over a TCP/IP network in render farms) PyroCluster (simulation of smoke and fire effects) Prime (the core application) Broadcast (adds MoGraph2) Visualize (adds Virtual Walkthrough, Advanced Render, Sky, Sketch and Toon, data exchange, camera matching) Studio (the complete package) == Version history == == Use in industry == A number of films and related works have been modeled and rendered in Cinema 4D, including: == Cinebench == Cinebench is a cross-platform test suite which tests a computer's hardware capabilities. It can be used as a test for Cinema 4D's 3D modeling, animation, motion graphic and rendering performance on multiple CPU cores. The program "target[s] a certain niche and [is] better suited for high-end desktop and workstation platforms". Cinebench is commonly used to demonstrate hardware capabilities at tech shows to show a CPU performance, especially by tech YouTubers and review sites.